beautypg.com

Troubleshooting – Porter-Cable CPFC2TV3525VP User Manual

Page 18

background image

18- ENG

N015840

TROUBLESHOOTING

Risk of Unsafe Operation. Unit cycles automatically when power is

on. When servicing, you may be exposed to voltage sources, compressed air, or

moving parts. Before servicing unit unplug or disconnect electrical supply to the air

compressor, bleed tank of pressure, and allow the air compressor to cool.

PROBLEM

CAUSE

CORRECTION

Excessive

tank pressure

- safety valve

pops off.

Pressure switch does not

shut off motor when

compressor reaches

"cut-out" pressure.

Move Auto/Off lever to the

"Off" position, if the outfit

does not shut off contact a

Trained Service Technician.

Pressure switch "cut-

out" too high.

Contact a Trained

Service Technician.

Air leaks at

fittings.

Tube fittings are not

tight enough.

Tighten fittings where air can

be heard escaping. Check

fittings with soapy water

solution.

Do Not Overtighten.

Air leaks

at or inside

check valve.

Check valve seat damaged.

A defective check valve results

in a constant air leak at the

pressure release valve when

there is pressure in the tank

and the compressor is shut

off. Replace check valve. Refer

to the

To Replace or Clean

Check Valve in the Service

and Adjustment section.

Air leaks at

pressure

switch release

valve.

Defective pressure

switch release valve.

Contact a Trained

Service Technician.

Air leaks in air

tank or at air

tank welds.

Defective air tank.

Air tank must be replaced.

Do not repair the leak.

Risk of

Bursting Do not drill into,

weld or otherwise modify air

tank or it will weaken. The

tank can rupture or explode.

Air leaks

between

head and

valve plate.

Leaking seal.

Contact a Trained

Service Technician.