beautypg.com

Porter-Cable CPFC2TV3525VP User Manual

Page 19

background image

19 - ENG

N015840

PROBLEM

CAUSE

CORRECTION

Pressure

reading on

the regulated

pressure

gauge drops

when an

accessory

is used.

It is normal for "some"

pressure drop to occur.

If there is an excessive

amount of pressure drop when

the accessory is used, adjust

the regulator following the

instructions in the

Description

of Operation paragraph

in the Operation section.
NOTE: Adjust the regulated

pressure under flow

conditions (while accessory

is being used).

knocking

Noise.

Possible defect in

safety valve.

Operate safety valve manually

by pulling on ring. If valve still

leaks, it should be replaced.

Defective check valve.

Remove and clean, or replace.

Compressor is

not supplying

enough air

to operate

accessories.

Prolonged excessive

use of air.

Decrease amount of air usage.

Compressor is not large

enough for air requirement.

Check the accessory

air requirement. If it is

higher than the SCFM or

pressure supplied by your

air compressor, you need

a

larger compressor.

Hole in hose.

Check and replace if required.

Check valve restricted.

Remove and clean, or replace.

Air leaks.

Tighten fittings.

Restricted air intake filter.

Clean or replace air intake

filter. Do not operate the

air compressor with the

filter removed. Refer to the

Air Filter paragraph in the

Maintenance section.

Regulator

knob has

continuous

air leak.

Damaged regulator.

Replace.

Regulator will

not shut off

air outlet.

Damaged regulator.

Replace.