Glossary – Porter-Cable CPFC2TV3525VP User Manual
Page 8

8- ENG
N015840
HAZARD
RISk FROM NOISE
WHAT CAN HAPPEN
HOW TO PREVENT IT
• Under some conditions and dura-
tion of use, noise from this product
may contribute to hearing loss.
• Always wear certified safe-
ty equipment: ANSI S12.6
(S3.19) hearing protection.
SAVE THESE INSTRUCTIONS
FOR FUTURE USE
SPECIFICATIONS
Model No.
CPFC2TV3525VP
Bore
2.375" (60.3 mm)
Stroke High Pressure
0.54" (14.0 mm)
Low Pressure
1.45" (37.0 mm)
Voltage/Hz-Single Phase
120
Minimum Branch Circuit Requirement
15 amps
Fuse Type
Time Delay
Air Tank Capacity (Gallon)
25 (94.6 Liter)
Approximate Cut-in Pressure
145 PSIG
Approximate Cut-out Pressure
175 PSIG
SCFM @ 40 psig
*5.8
SCFM @ 90 psig
*5.1
*Tested per ISO 1217
Refer to Glossary for abbreviations.
GLOSSARY
Become familiar with these terms before operating the unit.
CFM: Cubic feet per minute.
SCFM: Standard cubic feet per minute; a unit of measure of air delivery.
PSIG: Pounds per square inch gauge; a unit of measure of pressure.
Code Certification: Products that bear one or more of the following marks: UL,
CUL, ETL, CETL, have been evaluated by OSHA certified independent safety labo-
ratories and meet the applicable Underwriters Laboratories Standards for Safety.
Cut-In Pressure: While the motor is off, air tank pressure drops as you continue
to use your accessory. When the tank pressure drops to a certain low level the
motor will restart automatically. The low pressure at which the motor automatically
restarts is called "cut-in" pressure.
Cut-Out Pressure: When an air compressor is turned on and begins to run, air
pressure in the air tank begins to build. It builds to a certain high pressure before
the motor automatically shuts off - protecting your air tank from pressure higher
than its capacity. The high pressure at which the motor shuts off is called "cut-out"
pressure.
Branch Circuit: Circuit carrying electricity from electrical panel to outlet.