20- ENG

N015840

PROBLEM

CAUSE

CORRECTION

Motor will

not run.

Motor overload protection

switch has tripped.

Let motor cool off and

overload switch will

automatically reset.

Tank pressure exceeds

pressure switch "cut-

in" pressure.

Motor will start automatically

when tank pressure drops

below "cut-in" pressure

of pressure switch.

Extension cord is wrong

length or gauge.

Check for proper gauge

wire and cord length.

Check valve stuck open.

Remove and clean, or replace.

Loose electrical connections. Check wiring connection

inside pressure switch

and terminal box area.

Possible defective motor

or starting capacitor.

Have checked by a Trained

Service Technician.

Paint spray on internal

motor parts.

Have checked by a Trained

Service Technician. Do not

operate the compressor in

the paint spray area. See

flammable vapor warning.

Pressure release valve on

pressure switch has not

unloaded head pressure.

Bleed the line by pushing the

lever on the pressure switch to

the "Off" position; if the valve

does not open, replace switch.

Fuse blown, circuit

breaker tripped.

1. Check fuse box for blown

fuse and replace as

necessary. Reset circuit

breaker. Do not use a

fuse or circuit breaker

with higher rating than

that specified for your

particular branch circuit.

2. Check for proper

fuse. You should use

a time delay fuse.

3. Check for low voltage

conditions and/or proper

extension cord.

4. Disconnect the other

electrical appliances

from circuit or operate

the compressor on its

own branch circuit.