The BIOS logs the following SEL entries:
Table 26. BIOS Logging SEL List
Sensor Type
Sensor
Number
Sensor
Type
Code
Sensor-
Specific
Offset
Event
02h FRB1/BIST
Failure
03h
FRB2/Hang in POST failure
Processor 98h
99h
07h
05h
Configuration Error (for DMI)
Memory 08h
0Ch
01h
Uncorrectable ECC (If BMC not available)
POST Memory
Resize
A0h 0Eh -
POST
Memory
Resize
POST Error
06h
0Fh
-
POST Error
System
Event
87h 12h 00h System
Reconfigured
04h PCI
SERR
Critical
Interrupt
07h 13h
05h PCI
PERR
00h
Initiated by power up
03h
User requested PXE boot
System Boot
Initiated
A1h 1Dh
04h
Automatic boot to diagnostic
00h
No bootable media
Boot Error
A2h
1Eh
02h
PXE Server not found
06h
CMIC function 0 Errors
07h
CMIC function 1-3 Errors
Chipset Specific
Critical Interrupt
A9h F4h
08h
CIOBX2 #0 Errors
Table 27 below describes the various fields in the event request message, as sent by the BIOS.
(Regarding the detail, refer to the SHG2 Basic Input Output System (BIOS) External Product
Specification.)
Table 27. Event Request Message Event Data Field Contents
Event Trigger
Class
Event Data
Discrete
7:6
00 = Unspecified byte 2
01 = Previous state and/or severity in byte 2
10 = OEM code in byte 2
11 = Sensor specific event extension code in byte 2
5:4
00 = Unspecified byte 3
01 = Reserved
10 = OEM code in byte 3
11 = Sensor specific event extension code in byte 3
3:0
Offset from Event Trigger for discrete event state