14.2. Sensible Capacity Chart

CS-TE9DKE / CU-TE9DKE

230V

Outdoor Temp. (°C)

Indoor wet
bulb temp.

30

35

40

46

TC

SHC

IP

TC

SHC

IP

TC

SHC

IP

TC

SHC

IP

17.0°C

2.58

2.33

0.53

2.41

2.24

0.57

2.24

2.14

0.61

2.04

2.03

0.66

19.0°C

2.60

0.58

19.5°C

2.83

2.44

0.54

2.65

2.34

0.58

2.46

2.25

0.62

2.24

2.14

0.67

22.0°C

3.09

2.52

0.56

2.88

2.43

0.60

2.68

2.34

0.64

2.44

2.24

0.69

CS-TE12DKE / CU-TE12DKE

230V

Outdoor Temp. (°C)

Indoor wet
bulb temp.

30

35

40

46

TC

SHC

IP

TC

SHC

IP

TC

SHC

IP

TC

SHC

IP

17.0°C

3.42

2.86

0.82

3.20

2.75

0.89

2.97

2.64

0.95

2.70

2.51

1.02

19.0°C

3.45

0.95

19.5°C

3.76

3.01

0.84

3.51

2.89

0.90

3.27

2.78

0.97

2.97

2.64

1.04

22.0°C

4.10

3.12

0.85

3.83

3.06

0.92

3.56

2.89

0.99

3.24

2.75

1.06