Removal of control plate casing – Panasonic CU-TE12DKE User Manual
Page 71
13.4.2.3. Removal of Control Plate Casing
1. Remove the Cabinet Top Plate and Cabinet Front Plate
according to the item 13.5.2.1.
2. Remove the Control Cover (2- / 3-way valve Covers and
Terminal Cover) according to the item 13.5.2.2.
3. Remove the Control Plate Casing by releasing hooks (four:
two each on the right and left).
Fig. 5
4. Remove the screw (one) fixing the Control Plate Casing.
Fig. 6
5. Disconnect a variety of connectors and Terminals.
Wiring cables from lower side
•
•
•
•
Compressor cables (red, blue and yellow)
...... Disconnect the connector (white).
•
•
•
•
CN-HOT (white) ...... Electromagnetic Coil (4-way
valve) Cable: Yellow
•
•
•
•
Terminals connecting Reactor (two) Cable: Gray
•
•
•
•
CN-TANK (white) ...... Compressor Temp. Sensor
Wiring cables from left side
•
•
•
•
CN-FM1 ...... Outdoor Fan Motor
Wiring cables from right side
•
•
•
•
CN-STM
(white)
......
Electromagnetic
Coil
(Expansion Valve)
•
•
•
•
CN-TH (white) ...... Outdoor Air Temp. / Pipe Temp.
Sensor
6. Disconnect the interconnect cables and the Earth Wire (one
screw).
•
•
•
•
Remove the screws (two) fixing the Terminal part and
the Cabinet Side Plate (right).
Fig. 7
7. Remove the Control Plate Casing from the main unit by
holding it up.
Fig. 8
71