13.4.2.3. Removal of Control Plate Casing

1. Remove the Cabinet Top Plate and Cabinet Front Plate

according to the item 13.5.2.1.

2. Remove the Control Cover (2- / 3-way valve Covers and

Terminal Cover) according to the item 13.5.2.2.

3. Remove the Control Plate Casing by releasing hooks (four:

two each on the right and left).

Fig. 5

4. Remove the screw (one) fixing the Control Plate Casing.

Fig. 6

5. Disconnect a variety of connectors and Terminals.

Wiring cables from lower side

Compressor cables (red, blue and yellow)
...... Disconnect the connector (white).

CN-HOT (white) ...... Electromagnetic Coil (4-way
valve) Cable: Yellow

Terminals connecting Reactor (two) Cable: Gray

CN-TANK (white) ...... Compressor Temp. Sensor

Wiring cables from left side

CN-FM1 ...... Outdoor Fan Motor

Wiring cables from right side

CN-STM

(white)

......

Electromagnetic

Coil

(Expansion Valve)

CN-TH (white) ...... Outdoor Air Temp. / Pipe Temp.
Sensor

6. Disconnect the interconnect cables and the Earth Wire (one

screw).

Remove the screws (two) fixing the Terminal part and
the Cabinet Side Plate (right).

Fig. 7

7. Remove the Control Plate Casing from the main unit by

holding it up.

Fig. 8

71

CS-TE9DKE CU-TE9DKE / CS-TE12DKE CU-TE12DKE