$7 Alarm Port (ALARM)

This port accepts the alarm input from the associated
alarm sensors through either Normally Open or
Normally Closed contacts.
The pin assignment of the port is shown below.

$8 Copy Port (COPY)

For connecting the optional DVD Extension Unit.

$9 Mode Selector (MODE)

Selects data termination for PS

Data system expansion.

%0 Data Port (DATA)

Exchanges control data with the external device with
PS

Data (Panasonic Security Data) mode.

%1 Remote Port [REMOTE (WV-CU50)]

This port is provided for controlling the Disk Recorder
with the optional WV-CU50 Remote Controller.
To connect to the controller, use a 6-conductor modular
cable supplied as an accessory with the controller.

%2 Gen-lock Output Connector (GEN-LOCK OUT)

This connector is used to connect an external system
for synchronization.
To record images at maximum recording rate, for exam-
ple 60 fps, connect this output to the cameras to syn-
chronize the system.

%3 Serial Port (SERIAL)

For connecting a Personal Computer.

%4 Signal Ground Terminal (SIGNAL GND)

%5 10/100BASE-T Port (Optional)

An optional Network Board can be installed in the Disk
Recorder.
This port is used to exchange control data with Ethernet
via an Ethernet Hub.

%6 Cooling Fan

Prevents the temperature of the Recorder from rising.
Do not block the ventilation opening on the cover.

%7 AC Inlet Socket (AC IN)

Plug the power cord (supplied as a standard accesso-
ry) into this socket and connect it to an AC outlet.

%8 Power Switch (POWER ON/OFF)

This switch turns the power of the Disk Recorder on and
off.

%9 Video Output Connectors (VIDEO OUT 1 - 16)

The video signal connected to the Video Input
Connector (VIDEO IN) is looped through these connec-
tors with an automatic 75

Ω termination.

^0 Video Input Connectors (VIDEO IN 1 - 16)

These connectors accept either a color or B/W compos-
ite video signal from the camera.

Pin

No.

ALARM

1

13

14

25

Designation

1

2

3

4

5

6

7

8

9

10

11

12

13

Alarm Input 1

Alarm Input 2

Alarm Input 3

Alarm Input 4

Sequence Timing Input

Alarm Reset Output

Ground

Alarm Recover Input

Alarm Output

Alarm Input 10

Alarm Input 11

Alarm Input 12

Alarm Input 13

Pin

No.

14

15

16

17

18

19

20

21

22

23

24

25

Designation

Ground

Alarm Input 5

Alarm Input 6

Alarm Input 7

Alarm Input 8

Alarm Input 9

Ground

+5 V Output (0.2 A)

Recording Timer Select
Input

Alarm Input 14

Alarm Input 15

Alarm Input 16