beautypg.com

Plasmon LIBRARIES D2175 User Manual

Page 81

background image

Plasmon D875 - D2175 User Manual

Appendix D

Document Revision E

Page 79

4

Picker is 2nd destina-
tion element, src ele-
ment = 2nd dest
element

86

1

Element unexp
empty

No trays to use in cycle
Full test

Run Check Elements

2

Tray not seen during
pick attempt

87

1

Element unexp
full

Home sensor blocked
after store attempt

Obstruction
in path, Align-
ment problem

Check path, run offsets

2

Picker is full, attempting
to return tray to last ele-
ment

8B

1

Picker is full

VP or Pemt sensor
blocked by tray moving
to the pick position

Firmware,
Picker faulty

Tray in picker while picking,
initialize and retry, replace
picker

2

VP or Pemt sensor
blocked moving to the
unload drive position.

3

Both pickers are not
empty to do an
exchange (during
check move)

4

Picker full, not a move
to Lift and from Lift (dur-
ing check move)

5

SCSI exchange 2nd
destination picker,
source not picker

8C

1

Both pickers full

Check move, NVRAM
says both pickers full

Main control-
ler circuit
board, firm-
ware

Firmware recovery issue,
replace Main controller cir-
cuit board

2

Check single element,
NVRAM says both pick-
ers full

3

SCSI Mag door open,
both pickers full so
magazine can't be
checked

Error
Code

(hex)

Sub-

code

Error

Description

Subcode

Description

Compo-

nent

Corrective Action