Query auto setup setting, Query signal search, Query installation – Panasonic RS-232C User Manual
Page 39: Query high altitude mode
![background image](/manuals/173872/39/background.png)
39/49
2.119. Query AUTO SETUP setting
Hexadecimal 02h 51h 53h 53h
03h
Character Q S S
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *1 03h
Character *2
Acceptability
SECURITY STANDBY NO
SIGNAL AV MUTE REMOTE
○
×
○
○
○
Parameters (*1, *2)
BUTTON
AUTO
Hexadecimal 30h 31h
Character 0 1
2.120. Query SIGNAL SEARCH
Hexadecimal 02h 51h 53h 52h
03h
Character Q S R
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *1 03h
Character *2
Acceptability
SECURITY STANDBY NO
SIGNAL AV MUTE REMOTE
○
×
○
○
○
Parameters (*1, *2)
OFF
ON
Hexadecimal 30h 31h
Character 0 1
2.121. Query INSTALLATION
Hexadecimal 02h 51h 53h 50h
03h
Character Q S P
Response (Callback)
Hexadecimal 02h *1 03h
Character *2
Parameters (*1, *2)
FRONT/DESK
REAR/DESK FRONT/CEILING REAR/CEILING
Hexadecimal 30h
31h
32h
33h
Character 0
1
2
3
Acceptability
SECURITY STANDBY NO
SIGNAL AV MUTE REMOTE
○
○
○
○
○
2.122. Query HIGH ALTITUDE MODE
Hexadecimal 02h 51h 46h 4Dh
03h
Character Q F M
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *1 03h
Character *2
Acceptability
SECURITY STANDBY NO
SIGNAL AV MUTE REMOTE
○
○
○
○
○
Parameters (*1, *2)
OFF
ON
Hexadecimal 30h 31h
Character 0 1