2.55. SXGA MODE
Hexadecimal 02h 4Fh 53h 58h
3Ah
*1 03h
Character O S X : *2
Parameters (*1, *2)
SXGA
SXGA+
Hexadecimal 30h 31h
Character 0 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 53h 58h 3Ah *1 03h
Character O S X : *2
Acceptability
SECURITY STANDBY NO
SIGNAL AV MUTE REMOTE
Ч
Ч
Ч
Ч
○
2.56. WIDE MODE
Hexadecimal 02h 4Fh 58h 47h
3Ah
*1 03h
Character O X G : *2
Parameters (*1, *2)
OFF
ON
AUTO
Hexadecimal 30h 31h 32h
Character 0 1 2
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 58h 47h 3Ah *1 03h
Character O
X
G :
*2
Acceptability
SECURITY STANDBY NO
SIGNAL AV MUTE REMOTE
Ч
Ч
Ч
Ч
○
2.57. BACK COLOR
Hexadecimal 02h 4Fh 42h 43h
3Ah
*1 03h
Character O B C : *2
Parameters (*1, *2)
BLUE
BLACK
Hexadecimal 30h 31h
Character 0 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 42h 43h 3Ah *1 03h
Character O
B
C :
*2
Acceptability
SECURITY STANDBY NO
SIGNAL AV MUTE REMOTE
Ч
○
○
Ч
○
2.58. VOLUME
Hexadecimal 02h 41h 56h 4Ch
3Ah
*1 *3 *5 03h
Character A V L : *2 *4 *6
Parameters (*1, *2, *3, *4, *5, *6)
0
1
2
Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h
Character 0 0 0 0 0 1 0 0 2
61
62 63
Hexadecimal 30h 36h 31h 30h 36h 32h 30h 36h 33h
Character 0 6 1 0 6 2 0 6 3
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 41h 56h 4Ch 3Ah *1 *3 *5 03h
Character A
V
L
:
*2
*4
*6
Acceptability
SECURITY STANDBY NO
SIGNAL AV MUTE REMOTE
Ч
△
Ч
Ч
○
Note:
•
During STANDBY, this command is available only when IN STANDBY MODE is ON.