Basic control command, Explanatory notes, Power on (lamp on) – Panasonic RS-232C User Manual
Page 3: Power off (standby), Auto setup, Av mute

3/49
2. Basic Control Command
Explanatory notes
○
: Yes (Enable)
×
: No (Disable)
△
: Case by case (Refer to the note.)
2.1. Power ON (Lamp ON)
Hexadecimal 02h 50h 4Fh 4Eh 03h
Character P
O
N
Response (Callback)
In the period when the command can be accepted (This command in power-on condition is included.)
Hexadecimal 02h 50h 4Fh 4Eh 03h
Character P
O
N
Acceptability
SECURITY STANDBY NO
SIGNAL AV MUTE REMOTE
○
○
○
○
△
Notes:
•
When you confirm whether to have succeeded in power-on, confirm it by QPW (Query Power) command after
receiving the callback of PON command.
•
When REMOTE is effective, ER401 is returned as a response (callback).
2.2. Power OFF (Standby)
Hexadecimal 02h 50h 4Fh 46h 03h
Character P O F
Response (Callback)
In the period when the command can be accepted (This command in power-off condition is included.)
Hexadecimal 02h 50h 4Fh 46h 03h
Character P O F
Acceptability
SECURITY STANDBY NO
SIGNAL AV MUTE REMOTE
○
○
○
○
△
Notes:
•
When you confirm whether to have succeeded in power-off, confirm it by QPW (Query Power) command after
receiving the callback of POF command.
•
When REMOTE is effective, ER401 is returned as a response (callback).
2.3. AUTO
SETUP
Hexadecimal 02h 4Fh 41h 53h 03h
Character O
A
S
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 41h 53h 03h
Character O
A
S
Acceptability
SECURITY STANDBY NO
SIGNAL AV MUTE REMOTE
Ч
Ч
△
Ч
○
Note:
•
During NO SIGNAL, this command is available only when SIGNAL SEARCH is ON.
2.4. AV
MUTE
Hexadecimal 02h 4Fh 53h 48h
3Ah
*1 03h
Character O S H : *2
Parameters (*1, *2)
AV MUTE OFF
AV MUTE ON
Hexadecimal 30h
31h
Character 0
1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 53h 48h 3Ah *1 03h
Character O
S
H
:
*2
Acceptability
SECURITY STANDBY NO
SIGNAL AV MUTE REMOTE
Ч
Ч
○
○
○