Led meanings – Paradyne BitStorm 4800 Express User Manual
Page 32
3. LEDs
3-2
July 2004
4821-A2-GN21-10
LED Meanings
When power is first applied to the unit, it performs a power-on self-test. When this
test is successfully completed, the Status LED blinks. The meaning of all the LEDs
is shown in
.
Table 3-1.
Front Panel LEDs
LED
Color
State
Meaning
Link*
* The RJ45-type connectors for Port 1 and Port 2 bear two LEDs: the left one is the
Link LED and the right one is the Activity LED.
Green
Off
On
Flashing
No Ethernet link present.
Ethernet Link present.
Ethernet link is present, but port is
administratively disabled.
Activity*
Green
Off
On
No data is being transferred.
Data is being transferred.
STATUS
Green
Off
On
No power, or the unit has not completed
initialization.
Unit has power and has completed initialization.
ALARM
Amber
Off
On
No Alarms.
Unit failed self-test, or the unit has exceeded a
safe temperature, or a fan has failed.
TEST
Amber
Off
On
Normal operating mode.
At least one port is in test mode.
DSL Ports
(LEDs
numbered 1–24
or 1–48
correspond to
DSL ports 1–24
or 1–48)
Green
Off
On
The port is disabled or no signal is detected on
the line.
Port has successfully trained with the remote
and is active.