Consider the following before installing the BitStorm 4800 Express IP DSLAM:

„

Installation Site

Your installation site should be well ventilated, clean, and free of
environmental extremes.

„

Installation Options

The BitStorm 4800 Express may be:

— Mounted with the included mounting brackets in a standard 19-inch

(483 mm) or 23-inch (584 mm) rack (including both Bay Networks and
Nortel 23-inch racks), or, with separately purchased mounting brackets, in
a 21-inch (535 mm) ETSI rack. ETSI brackets are available from
Paradyne. See

Appendix B, Equipment List

.

As many BitStorm 4800 Express units may be mounted in a standard rack
as there are 1.75-inch (44.45 mm) spaces in the rack, so long as
adequate cooling is provided.

— Mounted vertically against a wall.

The standard mounting brackets provided can be fastened to the base of
the unit for wall mounting.

— Set on a shelf or desktop.

Up to five BitStorm 4800 Express units may be stacked on a shelf or
desktop.

„

Power

The BitStorm 4800 Express operates from a 90 to 265 VAC, 47 to 63 Hz power
source.

„

Cabling

No cable except the power cable is provided with the BitStorm 4800 Express.
See

Table 1-2, Cable Descriptions

, to determine what cables you need to

procure before installation.