Preparation – Paradyne BitStorm 4800 Express User Manual
Page 12
1. Installation
1-2
July 2004
4821-A2-GN21-10
Preparation
Consider the following before installing the BitStorm 4800 Express IP DSLAM:
Installation Site
Your installation site should be well ventilated, clean, and free of
environmental extremes.
Installation Options
The BitStorm 4800 Express may be:
— Mounted with the included mounting brackets in a standard 19-inch
(483 mm) or 23-inch (584 mm) rack (including both Bay Networks and
Nortel 23-inch racks), or, with separately purchased mounting brackets, in
a 21-inch (535 mm) ETSI rack. ETSI brackets are available from
Paradyne. See
.
As many BitStorm 4800 Express units may be mounted in a standard rack
as there are 1.75-inch (44.45 mm) spaces in the rack, so long as
adequate cooling is provided.
— Mounted vertically against a wall.
The standard mounting brackets provided can be fastened to the base of
the unit for wall mounting.
— Set on a shelf or desktop.
Up to five BitStorm 4800 Express units may be stacked on a shelf or
desktop.
Power
The BitStorm 4800 Express operates from a 90 to 265 VAC, 47 to 63 Hz power
source.
Cabling
No cable except the power cable is provided with the BitStorm 4800 Express.
See
Table 1-2, Cable Descriptions
, to determine what cables you need to
procure before installation.