beautypg.com

Procedure of lamp unit replacement, Caution – Panasonic PT-D7500U User Manual

Page 96

background image

96

Replacement of lamp unit

• After 1 500 hours of operating the same lamp, it is only possible to operate the unit for approximately

10 minutes. Steps 8 to 14 must be completed within ten minutes.

1. Turn the power off by following the steps on pages 39 ~ 40, remove the power plug

and confirm that the surroundings of the lamp unit have cooled off.

2. Using a Philips screwdriver, remove

the 7 screws on the lamp unit cover
located on the rear of the projector.

3. Remove the lamp unit housing door

from the main unit.

4. Use a Phillips screwdriver to loosen

the two lamp unit fixing screws until
the screws turn freely. Then hold the
handle of the lamp unit and gently pull
it out from the projector.

Caution

The lamp unit will be hot after it has
been used.

You might get burned if you touch it while it is still
hot.

5. Install the new lamp unit.

6. Use a Phillips screwdriver to securely tighten the lamp unit fixing 2 screws.

7. Install the lamp unit cover, and then

use a Phillips screwdriver to securely
tighten the lamp unit cover fixing 7
screws.

• Firmly install the lamp unit and lamp

unit cover. If not installed firmly, a
protection circuit will function and the
power will not be turned on.

Procedure of lamp unit replacement

Lamp unit cover

Fixing screws

Lamp unit

Fixing screws

Handle

Lamp unit

Fixing screws

Lamp unit 2

Lamp unit 1

Lamp unit cover

Fixing screws

Caution

Caution