Paradyne Hotwire ATM Line Cards 8385 User Manual
Page 95
5. Diagnostics
8335-A2-GB20-70
February 2003
5-9
Card Alarms Screen – Model 8385
D-B
Displays alarms for the card and port levels. Columns on this screen represent port
numbers (01– 24). If Next appears, press Enter to display the next 12 ports (13–24); if
Previous appears, press Enter to display previous page of ports (01–12).
Major Alarms:
Selftest – Shown as Pass or Fail.
ATM Bus Failure – If ALARM appears on this line, there has been a Loss Of Clock (LOC)
because the line card is unable to communicate with the SCM. This could be because the
chassis does not support the ATM bus (the chassis is not an 8620 or 8820 GranDSLAM),
or the SCM card has been removed from the chassis.
DSL Port Selftest Failure – DSL port self-test results. A result code is shown for each
port: P for Pass or F for Fail.
(Continued on next page)
Table 5-2.
Monitoring – Card Alarms (5 of 6)