beautypg.com

2 configuring dip switch sw, Switches sw-2 and sw-4: data rate, Switches sw-1 and sw-5 through sw-8: reserved – Patton electronic CopperLink Ethernet Extenders 2168A User Manual

Page 17: Configuring dip switch sw

background image

17

4.2 CONFIGURING DIP SWITCH SW

DIP switch SW is where you configure the CopperLink line rate, and if
the rate is symmetric or asymmetric.

Switches SW-2 and SW-4: Data Rate

Use switches SW-2 and SW-4 to configure the CopperLink line rates.

Note

Table 2 only applies to Models 2168A and 2168A/TB45.

Switches SW-1 and SW-5 through SW-8: Reserved

Table 1:

Symmetric CopperLink Line Rates Selection Chart

SW-2

SW-3

SW-4

Symmetric Line Rate

ON

ON

ON

6.25 Mbps

ON

ON

OFF

9.38 Mbps

ON

OFF

OFF

12.5 Mbps (Factory Default)

*

*. Model 2158A only has one symmetric line

rate setting, which is 12.5 Mbps.

ON

OFF

ON

16.67 Mbps

Table 2:

Model 2168A and 2168A/TB45 Asymmetric CopperLink Line Rates Selection Chart

SW-2

SW-3

SW-4

Asymmetric Line Rates DS/US

*

*. DS = downstream from L unit to R unit

US = upstream from R unit to L unit

OFF

OFF

ON

4.17 Mbps/1.56 Mbps

OFF

ON

ON

9.38 Mbps/1.56 Mbps

OFF

ON

OFF

16.67 Mbps/2.34 Mbps

Table 3:

Reserved for future use

SW-1

SW-5

SW-6

SW-7

SW-8

Reserved for future use

OFF

OFF

OFF

OFF

OFF

Reserved

(Factory Default)