2 configuring dip switch sw, Switches sw-2 and sw-4: data rate, Switches sw-1 and sw-5 through sw-8: reserved – Patton electronic CopperLink Ethernet Extenders 2168A User Manual
Page 17: Configuring dip switch sw

17
4.2 CONFIGURING DIP SWITCH SW
DIP switch SW is where you configure the CopperLink line rate, and if
the rate is symmetric or asymmetric.
Switches SW-2 and SW-4: Data Rate
Use switches SW-2 and SW-4 to configure the CopperLink line rates.
Note
Table 2 only applies to Models 2168A and 2168A/TB45.
Switches SW-1 and SW-5 through SW-8: Reserved
Table 1:
Symmetric CopperLink Line Rates Selection Chart
SW-2
SW-3
SW-4
Symmetric Line Rate
ON
ON
ON
6.25 Mbps
ON
ON
OFF
9.38 Mbps
ON
OFF
OFF
12.5 Mbps (Factory Default)
*
*. Model 2158A only has one symmetric line
rate setting, which is 12.5 Mbps.
ON
OFF
ON
16.67 Mbps
Table 2:
Model 2168A and 2168A/TB45 Asymmetric CopperLink Line Rates Selection Chart
SW-2
SW-3
SW-4
Asymmetric Line Rates DS/US
*
*. DS = downstream from L unit to R unit
US = upstream from R unit to L unit
OFF
OFF
ON
4.17 Mbps/1.56 Mbps
OFF
ON
ON
9.38 Mbps/1.56 Mbps
OFF
ON
OFF
16.67 Mbps/2.34 Mbps
Table 3:
Reserved for future use
SW-1
SW-5
SW-6
SW-7
SW-8
Reserved for future use
OFF
OFF
OFF
OFF
OFF
Reserved
(Factory Default)