Cis assembly service check, Cis assembly service – Lexmark 4200 Series User Manual
Page 24

2-8
Service Manual
4413-XXX
CIS assembly service check
The CIS lamp does not light when scanning is in process.
6
Maintenance
Station
A problem with the maintenance station can cause
carrier movement problems at the right margin. Go
to the
“Maintenance station removal” on
.
7
Access Door
Sensor
If the carrier does not move toward the cartridge
load position when the access door is opened,
verify that power is on. If the carrier still does not
move, replace the system board. Go to the
“System board removal” on page 4-19
.
FRU
Action
1
CIS Assembly
If light does not come on during the
scanning process, check connector
CN6 on the system board. If the
connection is okay, replace the CIS
assembly. Go to the
Image Sensor) removal” on
page 4-10
. If problem still persists,
replace the system board. Go to the
“System board removal” on
page 4-19
.
FRU
Action
- E260d (142 pages)
- 6600 Series (173 pages)
- 10N0227 (1 page)
- Z12 (2 pages)
- 301 (144 pages)
- NO. 35 (1 page)
- Z65n (111 pages)
- dn2 (217 pages)
- 10E (144 pages)
- Z2300 (54 pages)
- 230 (213 pages)
- 310 Series (2 pages)
- PRO700 (24 pages)
- C 720 (18 pages)
- C520 (145 pages)
- X656 MFP (104 pages)
- Prospect Pro207 (27 pages)
- 337 (258 pages)
- OptraImage 242 (207 pages)
- T64x (6 pages)
- C524 (146 pages)
- 4098-001 (70 pages)
- 1200 Series (21 pages)
- X650 Series (8 pages)
- 5300 (179 pages)
- 302 (274 pages)
- 4549 (235 pages)
- 202 (320 pages)
- 4076-0XX (89 pages)
- 10N0016 (1 page)
- 5025 (171 pages)
- 1361760 (1 page)
- C 546dtn (6 pages)
- Interpret S400 (40 pages)
- x6575 (2 pages)
- 27S2156-001 (2 pages)
- MENUS AND MESSAGES C522 (55 pages)
- Z35 (101 pages)
- Z25 (24 pages)
- series x5100 (77 pages)
- Z82 (105 pages)
- 2500 Series (76 pages)
- 1200 (208 pages)
- Z33 (114 pages)
- 7600 Series (181 pages)