Troubleshooting, Caution – Lincoln Electric IM613-B User Manual

Page 44

background image

E-10

TROUBLESHOOTING

E-10

POWER FEED 11

Observe all Safety Guidelines detailed throughout this manual

Note: For any Err # listed below write down the error number for reference and try cycling power to see if the

error clears itself. If not, refer to the What to Do column for the given Err.

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE CAUSE

RECOMMENDED

COURSE OF ACTION

Display shows any of the following:

Err

001

Err

003

Err 004

Err

005

Err 006

More than 1 CB with the same group
number.

Too many objects in group.

More than 1 object of the same
equipment type with the same group
# and feed head #.

A feed head has its feed head dip
switches set to zero in a group with
more than one object.

Did not receive a recognition com-
mand from the power source.

Make sure the group dip switch set-
ting is unique for each CB.

A given group can only support up to
7 objects. Remove any objects over
7 from the group either by changing
the group dip switch settings or
physically disconnecting any objects
over 7 in the group.

Adjust the dip switch setting to make
either the group # or feed head #
unique for all objects of the same
equipment type.

The appropriate feed head # is 1
through 7. Check the dip switch set-
ting chart in INSTALLATION section
and set the switches to make the
Feed head ID non-zero.

Check to see if the status light is not
solid green on the power source
(refer to status light states in OPER-
ATION section if not). Also, check
continuity in the communication lines
from CB to Power Source (refer to
wiring diagram). Refer to Power
source trouble shooting section for
additional information. If all these
avenues fail, replace CB mother PC
board.