PROBLEMS

(SYMPTOMS)

POSSIBLE CAUSE

RECOMMENDED

COURSE OF ACTION

17. Dual Procedure is not function-

ing when using the local dual
procedure switch (on CB).
Status lights are solid green on
CB and Head boards.

18. Wire feed speed is consistent

and adjustable, but operates at
the wrong speed.

19. Status LED not solid green

a. Faulty local dual procedure

switch or CB mother board.
Disconnect harness plug from J5
of CB mother board. Check that
there is continuity between plug
pins 1 and 7 local DPS is in posi-
tion “A” but not when in gun or
“B”. Now check that there is con-
tinuity between plug pins 1and 8
when local DPS is in position “B”
but not when in “Gun” or “A”. If
any of these continuity tests fail,
repair or replace switch or switch
harness to correct the problem,
Otherwise, replace CB mother
board.

a. Dip switch on feed head board

does not match gear ratio used at
gear box. If using a high speed
gear, the feed head PC board dip
switch 8 must be set to 1 or “ON”.

b. Feed head board is not properly

reading DIP switch. Replace feed
head PC board.

a. see LED Status Light Chart.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.