beautypg.com

Troubleshooting, Caution – Lincoln Electric IM613-B User Manual

Page 39

background image

E-5

TROUBLESHOOTING

E-5

POWER FEED 11

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE CAUSE

RECOMMENDED

COURSE OF ACTION

7. No wire feed, solenoid, or arc

voltage. Status LEDs are solid
green.

8. No control of wire feed.
All status lights are solid green.
Preset WFS is adjustable on Control
Box

9. Wire feed motor turns and sole-

noid operates, but no arc voltage
is present. Status light is solid
green on Control Box.

a. Faulty gun trigger switch. The gun

trigger switch or circuit may be
faulty. Check or Replace.

a. Defective motor tach or control

PC board, or harness. Check for
loose or faulty connections on
motor tach. See Wiring Diagram.

a. Power source is unable to

respond due to thermal or other
type of shut down mode.

b. Power source is defective. See

Power Source LED Status Light
Chart.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.