Installation, Dip switch setup, A-6 figure a.3 – Lincoln Electric IM613-B User Manual
Page 14: Setting dip switches in the control box
A-6
INSTALLATION
POWER FEED 11
A-6
FIGURE A.3
DIP SWITCH SETUP
SETTING DIP SWITCHES IN THE
CONTROL BOX
There are two DIP switch banks on the mother board
of the Control Box. They are labeled S1 and S2 and
are located and oriented as shown in Figure A.3.
S1
ON
1
2
3
4
5
6
7
8
S2
ON
1
2
3
4
5
6
7
8
S1 DIP Switch Bank on Control Box Motherboard (For Software version S24456-1)
Switch
Off
On
1
Standard speed limits adjustable
High speed gearbox limits adjustable
2
WFS Display = inches/minute
WFS Display = meters/minute
3
Left Display is always preset WFS
Left Display is preset WFS when weld current is not flowing
Left Display is actual weld current when weld current is flowing
CC modes override this switch regardless of position. Left Display is always preset weld cur-
rent when weld current is not flowing and actual weld current when weld current is flowing
4
Run-in = Minimum Speed Available
Run-in = weld WFS
If any option containing a Run-in setting is connected to the motherboard, it automatically
overrides this switch regardless of position.
5
Memory change with trigger disabled
Memory change with trigger enabled
6
Acceleration, MSB (Sets acceleration rate for wire drive) see below
7
Acceleration (Sets acceleration rate for wire drive) see below
8
Acceleration, LSB (Sets acceleration rate for wire drive) see below
DIP SWITCH 6
DIP SWITCH 7
DIP SWITCH 8
Acceleration 1 (slow)
Off
Off
On
Acceleration 2
Off
On
Off
Acceleration 3
Off
On
On
Acceleration 4
On
Off
Off
Acceleration 5 (fast ) (factory setting)
Off
Off
Off
Note: the factory shipped settings for Switch S1 are as follows:
PF-11 European - Switches 1-2 “ON”; Switches 3-8 “OFF”
PF-11 World - Switch 1 “ON”; Switches 2-8 “OFF”