beautypg.com

LG G4F-AD3A User Manual

Page 46

background image

Chapter 5. GM PROGRAMMING


5 -9

4) Programming example

Execution condition

and initial setting

Execution request when the

initializing function block is not

operated

It indicates on when operated normally,

and off when operated abnormally or down

from Live data of opposite station

It indicates information on

power-off state of opposite

station. If restored, it turns

“On” and the “On” state is

retained until the user

program turns it “Off”.

Slot location number of master

communication module

Address of remote

station

Base location number of

A/D conversion module

Slot location number of

A/D conversion module

Available channel enable

specification

Conversion data range

specification

Average processing

enable/disable specification

Average processing

number specification

Execution request on the reading function

block with communication intervals.

Slot location number of

master communication module

Address of remote station

Base location number of

A/D conversion module

Slot location number of

A/D conversion module

Error data display

Error code display at

occurring error

Normal channel

operation display

Error data display in processing of

initialization function block

Error code display in processing of

initialization function block

Normal channel operation

display

The digital value less than

2000 of channel 0

turns %Q0.1.0 on.

The digital value more than

2000 or same, and less than

3000 or same turns %Q0.1.1

on.

The digital value more than

3000 or same, and less

than 4000 turns %Q0.1.2

on.

The digital value more than

12000 or same

turns %Q0.1.3 on.

A/D conversion value

READY

START

AD_INI

ADR3INI

REQ

NDR

NET_

NO

NDR

ST_

NO
BASE

STAT

ACT

SLOT

CH

TYPE

AVG

_EN

0

1

0

SRD_ST

INI_ACT

AC_CH

INI_STAT

INPUT TYPE

AVG_EN

AVG_NUM

MOVE

EN

ENO

IN1

OUT

0

READY

Line 0

Line 1

Line 2

Line 3

Line 4

Line 5

Line 6

Line 7

Line 8

Line 9

Line 10

Line 11

Lind 12

Line 13

Line 14

Line 15

Line 16

Line 17

Line 18

Line 19

Line 20

Line 21

Line 22

Line 23

Line 24

Line 25

Line 26

Line 27

Line 28

START

_NETO_LIV[1]

0

AVG

_NUM

S

_NETO_RST[1] _NETO_LIV[1]

MOVE

EN

ENO

IN1

OUT

0

_NETO_RST[1]

START

AD_RD.NDR _NETO_LIV[1]

AD_RD

ADR3RD

REQ

NDR

NET_

NO

ERR

ST_

NO
BASE

STAT

ACT

SLOT

0

1

0

RD_ERR

RD_ACT

RD_STAT

0

DATA AD_DATA

CH

AD_CH

LT

EN

ENO

IN1

OUT

AD_DATA[0]

% Q0.1.0

IN2

2000

GE

EN

ENO

IN1

OUT

AD_DATA[0]

IN2

2000

LT

EN

ENO

IN1

OUT

AD_DATA[0]

% Q0.1.1

IN2

3000

GE

EN

ENO

IN1

OUT

AD_DATA[0]

IN2

3000

LT

EN

ENO

IN1

OUT

AD_DATA[0]

% Q0.1.2

IN2

4000

GE

EN

ENO

IN1

OUT

AD_DATA[0]

% Q0.1.2

IN2

4000

This manual is related to the following products: