Lowrance electronic 540c Baja User Manual
Page 153
145
3. Select the EP-15 Fluid Level and press
ENT
.
4. Press
↓ to select
C
ALIBRATE
and press
ENT
. The Device Calibration
menu will appear. Instructions on Calibration will be listed at the top
of the menu.
5. Highlight
N
UM
P
TS
,
press
ENT
and select
2.
Press
ENT
.
6.
Select F
LUID
L
EVEL
, press ENT, then select E
MPTY
L
EVEL
and
press
ENT.
7. Make sure the fuel tank is empty, highlight
C
ALIBRATE
and press
ENT
.
The following message will appear: Empty Level Calibration Com-
pleted.
Press ENT.
8.
Fill up your tank, highlight
F
LUID
L
EVEL
and press
ENT.
9.
Select
F
ULL
L
EVEL
and press
ENT.
Highlight
C
ALIBRATE
and press
ENT.
10.
The following message will appear
:
Full level Calibration Com-
pleted.
Press
ENT
, then press
EXIT
repeatedly to get back to the main
display.
Calibrate is highlighted on the device configuration menu (left). Cali-
bration menu (right) with calibration instructions listed at the top.
3-Point Calibration
3-point calibration is designed for tanks that vary in shape from the top
to the bottom. You can begin calibration at any point in the 3-point
process, but we recommend starting calibration with an empty tank.
In a 3-point calibration, you will set three points, one each for empty,
half and full levels.
1. Press
MENU| MENU
, use
↓ ↑ to select
NMEA
2000
and press
ENT
.
2. Highlight
B
US
S
ETUP
and press
ENT
, which will open the Bus Configu-
ration menu. A list of network devices will be at the top of the page. 3.
Select the EP-15 Fluid Level and press
ENT
.