NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

(B) Removing Photoeye Filter for Cleaning:

1. Lift off cover plate and turn over (the photoeye is attached to the inside

surface of cover). Wipe away any dust or debris from the photoeye
lens (see Figure 53).

CAUTION: If the fi lter is not reinstalled, refl ective light in the room may
result in a fault, thus shutting down of the unit.

Photoeye Access Inside Hopper

To access photoeye, open hopper and remove

the 3 nuts on cover plate (see picture below).

Photoeye Cover
Plate

Using a 11/32” nut
driver remove the 3 nuts
to access photoeye and
fi lter.

Clean Photoeye Lens

Clean Photoeye Lens

Remove Filter and Wipe Clean

Filter

(Minimum frequency of 4 weeks - 6 months)

Figure 53 - Clean Photoeye Lens and Filter

2. Clean Filter as follows: With the photoeye cover plate removed, look

inside the opening. You will see an amber colored square glass fi lter
secured in place by a bracket and 2 nuts. Using an 11/32” nut driver,
remove the 2 nuts and lift off the bracket. Using your fi nger slide fi lter
up and out.

3. Wipe away any dust or debris on fi lter, then reinstall fi lter, fi lter bracket

and cover plate with photoeye.

IMPORTANT: When reinstalling photoeye and cover, be careful not to
damage the wires. Pay special attention in positioning wires away
from photoeye (which could obstruct it from sensing light).

Opening Side Panels

Profi le

®

30 FS-2:

1) Using a 1/4” nut driver, remove the screw from underneath the side

panel at the front edge (see Figure 54).

2) Pull panel outward (on the upper portion of side panel) until the 2 ball

studs on the inside of the panel releases. Note: The side panel will
hinge open from the front.

3) After maintenance is complete, reinstall the retaining screw to

prevent the panel from being accidentally opened.

Remove side panel
retaining screw.

Figure 54 - Opening Side Panels, Profi le 30 FS-2

Profi le 20 FS-2:

1) Using a 1/4” nut driver remove the screw located at the front top of

the panel (see Figure 55).

2) Pull panel outward (on lower portion of side panel) until the ball stud

on the inside of the panel releases. Note: The side panel will hinge
open from the front.

3) After maintenance is complete, reinstall the retaining screw to

prevent the panel from being accidentally opened.