beautypg.com

Lennox Hearth WHITFIELD 30 FS-2 User Manual

Page 13

background image

13

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

Determining Size Of Pipe To Install

To determine what diameter pipe to use in an installation (3” or 4”), fi rst
fi nd the “equivalent pipe length” using the following guidelines, then plot
this Figure and the altitude on the chart.

Fill out the installation chart, and calculate your total equivalent pipe
length. After you have the total equivalent pipe length, use the Pipe
Selection Chart below to determine if your installation requires 3” or 4”
exhaust pipe.

Installation Chart

4 Inch Diameter Only

3 or 4 Inch

Diameter

Altitude x 1000 Feet

Equivalent Pipe Length (Feet)

30

20

10

0

0

1

2

3

4

5

6

7

8

9

10

Figure 19

- Pipe Selection Chart

A

B

C

D

E

F

G

H

Figure 20

- See Sample Installation Chart

A- 90 Degree Elbow
B- 1’ Horizontal Pipe
C- 45 Degree Elbow
D- Standoff Braces
E- 8’ Vertical Pipe
F- 2’ Horizontal Pipe
G- 90 Degree Tee
H- Wall Thimble

NOTE: All equivalent pipe styles
shown are standard for all free-
standing models.

Type of Pipe

# of Elbows or
Feet of pipe

Equivalent Feet

Total Equivalent
Feet

90° Elbows /
Tee (A & G)

x

5 Feet

(1.5 meters)

45° Elbows
(C)

x

3 Feet

(1 meters)

Horizontal
(B & F)

x

1 foot

(.3 meters)

Vertical(E)

x

.5 Feet

(.15 meters)

Table 5

Sample Installation Chart

Type of Pipe

# of Elbows or
Feet of pipe

Equivalent Feet

Total Equivalent
Feet

90° Elbows /
Tee (A & G)

2

x

5 Feet

(1.5 meters)

10 Feet

(3 meters)

45° Elbows
(C)

1

x

3 Feet

(1 meter)

3 Feet

(1 meters)

Horizontal
(B & F)

3

x

1 foot

(.3 meters)

3 Feet

(1 meter)

Vertical(E)

8

x

.5 Feet

(.15 meters)

4 Feet

(1.2 meters)

Table 6

- Sample Chart for Figure 16

This manual is related to the following products: