Lennox Hearth WHITFIELD 30 FS-2 User Manual

Page 15

background image

15

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

3” (75 mm) Minimum
clearance between
wall and pipe. If you
vent to the furthest
wall, the vent pipe
must maintain a 3”
clearance parallel to
the other wall.

Top View Illustration

Wall

Top View Illustration

Wall

2" Min.

2" Min.

Wall

3” (75 mm) Minimum
clearance between wall
and pipe. If you vent to
the furthest wall, the vent
pipe must maintain a 3”
clearance parallel to the
other wall.

Top View Illustration

Wall

2" Min.

2" Min.

6” / 152 mm
Minimum

Hearth Pad / Floor Protection

12” / 305 mm From
Ground or Other Surface

45 Degree

Elbow

2” / 51 mm

Minimum

12” (305 mm)
Minimum From
Outer Wall

Figure 22 - Corner Through the Wall, Profi le 30 FS-2*

Figure 23 - Corner Through the Wall, Profi le 20 FS-2*

Figure 24 - Parallel Through the Wall, Profi le 20 FS and Profi le 30 FS

Wall

Outdoors

Standard Horizontal Installation Confi gurations
Profi le

®

20 FS-2 and Profi le 30 FS-2

* Note: Horizontal run of pipe requires 1/4” (7 mm) rise per foot.