LSI 7202CP User Manual
Page 26
3-8
BIOS Features
Copyright © 2001, 2002 by LSI Logic Corporation. All rights reserved.
2.
Does the LED on the adapter indicate LINK? (note that LINK is only
valid after the device is probed)
3.
Does the LED on the switch or remote enclosure indicate LINK?
4.
Does the LINK-SPEED parameter selected by the adapter match
that of the bus (
1G
,
2G
, or
Auto
)?
If you do not see disks, the following additional debug information may
help to identify the problem.
3.1.5.3 Verifying Correct Installation
Use this procedure to verify installation of your Fusion-MPT adapter in
the system:
Step 1.
Power on the system.
Step 2.
When the banner displays, press the
Stop-A
keys to interrupt
the boot process and stop at the
ok
prompt.
Step 3.
Use the
show-devs
command to list the system devices. You
should see an output similar to the following:
ok show-devs
/SUNW,UltraSPARC-III@0,0
/virtual-memory
/memory@m0,0
/aliases
/options
/openprom
/chosen
/packages
/upa@8,480000/SUNW,ffb@0,0
...
/pci@8,700000/IntraServer,fc@2
/pci@8,700000/IntraServer,fc@1,1
/pci@8,700000/IntraServer,fc@1
...
/pci@8,700000/IntraServer,fc@2/disk
/pci@8,700000/IntraServer,fc@2/tape
/pci@8,700000/IntraServer,fc@1,1/disk
/pci@8,700000/IntraServer,fc@1,1/tape
/pci@8,700000/IntraServer,fc@1/disk
/pci@8,700000/IntraServer,fc@1/tape
/pci@8,700000/scsi@6,1/tape
/pci@8,700000/scsi@6,1/disk