Variable list – Loctite CARTESIAN 400 User Manual
Page 26

VARIABLE LIST
 
Built-in variables, which are built-in as robot functions, and user definition variables, which can be 
freely defined, can be used with this robot. 
User definition variables, except local variables (variables effective only in defined point job data 
which are defined by the “declear” command), are defined in the customizing mode. (Refer to the 
operation manual “Features IV” for a description of the customizing mode.) 
 
Boolean type 
1 bit variable (Holds only a value of 1 (true) or 0 (false).)
Numeric type
8 bytes real type (double type) variable.
String type
255 bytes variable
Category Type Identifier
Description
boo
#mv(1 to 99)
Boolean variable
boo
#mkv(1 to 99)
Boolean variable (keeping variable)
num
#nv(1 to 99)
Numeric variable
num
#nkv(1 to 99)
Numeric variable (keeping variable)
str
#sv(1 to 99)
String variable
Free 
Variable 
str
#skv(1 to 99)
String variable (keeping variable)
boo
#sysIn1 to 15
I/O-SYS
boo #genIn1
to
18
I/O-1
Input 
Variable 
boo
#handIn1 to 4
I/O-H
boo
#sysOut1 to 14
I/O-SYS
boo
#genOut1 to 22
I/O-1
Output 
Variable 
boo #handOut1
to
4
I/O-H
System 
Flag 
boo
#sysFlag(1) to #sysFlag(999) Refer to the system flag table.
boo #FBZ
set #FBZ : Sound buzzer. 
reset #FBZ : Stop buzzer. 
Buzzer
(onoffBZ : Sound buzzer intermittently.)
num #downTimer1
to
10
When a value is assigned, it counts down 
automatically. (msec units) 
Special 
Variable 
num #jobStartHight
Start a point job from an assigned value 
above the set point Z coordinate. (Disabled in 
CP drive) 
boo
#palletFlag(1 to 100)
Pallet flag (corresponds to pallet 1 to 100)
Pallet
num
#palletCount(1 to 100)
Pallet counter (corresponds to pallet 1 to 100)
num
#workAdj_X(1 to 100) 
#workAdj_Y(1 to 100) 
#workAdj_Z(1 to 100) 
Workpiece 
Adjustment 
#workAdj_R(1 to 100) 
#workAdj_Rotation(1 to 100) 
Workpiece adjustment amount of each axis 
(Corresponds to workpiece adjustment 1 to 
100) 
“Keeping variable” is a variable which holds its value even when the robot power is turned off.
Features II CARTESIAN Benchtop Robot
8