beautypg.com

Lenovo THINKSERVER 3797 User Manual

Page 220

background image

1

Handle

2

Latch

3

Filler panel handle

To install a drive in a hot-swap bay, complete the following steps.

Attention:

To maintain proper system cooling, do not operate the server for more

than 10 minutes without either a drive or a filler panel installed in each bay.

1. Orient the drive as shown in the illustration.

2. Make sure that the tray handle is open.

3. Align the drive assembly with the guide rails in the bay.

4. Gently push the drive assembly into the bay until the drive stops.

5. Push the tray handle to the closed (locked) position.

6. If the system is turned on, check the hard disk drive status LED to verify that

the hard disk drive is operating correctly.

After you replace a failed hard disk drive, the green activity LED flashes as the disk
spins up. The amber LED turns off after approximately 1 minute. If the new drive
starts to rebuild, the amber LED flashes slowly, and the green activity LED remains
lit during the rebuild process. If the amber LED remains lit, see “Hard disk drive
problems” on page 144.

Note: You might have to reconfigure the disk arrays after you install hard disk

drives.

212

ThinkServer RD220 Types 3729, 3779, 3797, and 3798: Hardware Maintenance Manual

This manual is related to the following products: