Table 3. DSA diagnostic messages (continued)

v

Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See Chapter 7, “Parts listing, ThinkServer RD220 Type 3729, 3779, 3797, and 3798,” on page 231 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

Message
number

Component

Test

State

Description

Action

215-902-xxx

Optical Drive

v

Verify
Media
Installed

v

Read/
Write
Test

v

Self-Test

Messages
and actions
apply to all
three tests.

Failed

Read
miscompare.

1. Insert a CD or DVD into the drive or

try a new media, and wait for 15
seconds.

2. Run the test again.

3. Check the drive cabling at both ends

for loose or broken connections or
damage to the cable. Replace the
cable if it is damaged.

4. Run the test again.

5. For additional troubleshooting

information, go to
http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-41559.

6. Run the test again.

7. Replace the CD or DVD drive (see

“Removing a CD-RW/DVD drive” on
page 213
and “Installing a
CD-RW/DVD drive” on page 214).

8. If the failure remains, collect the data

from the DSA event log and send it to
IBM Service. For information about
contacting and sending data to IBM
Service, see http://www.ibm.com/
support/
docview.wss?uid=psg1SERVCALL.

118

ThinkServer RD220 Types 3729, 3779, 3797, and 3798: Hardware Maintenance Manual