Hard disk drive problems, Solving microprocessor problems, Solving ethernet controller problems – Lenovo THINKSERVER 3797 User Manual

Page 152

background image

Hard disk drive problems

v

Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

Symptom

Action

Not all drives are recognized by
the hard disk drive diagnostic
test (the Fixed Disk test).

Remove the drive that is indicated by the diagnostic tests; then, run the hard disk
drive diagnostic test again. If the remaining drives are recognized, replace the drive
that you removed with a new one.

The server stops responding
during the hard disk drive
diagnostic test.

Remove the hard disk drive that was being tested when the server stopped
responding, and run the diagnostic test again. If the hard disk drive diagnostic test
runs successfully, replace the drive that you removed with a new one.

A hard disk drive was not
detected while the operating
system was being started.

Reseat all hard disk drives and cables; then, run the hard disk drive diagnostic
tests again.

A hard disk drive passes the
diagnostic Fixed Disk Test, but
the problem remains.

Run the diagnostic SCSI Attached Disk Test.

Solving Microprocessor problems

v

Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

Symptom

Action

The server emits a continuous
beep during POST, indicating
that the microprocessor is not
working correctly.

1. Correct any errors that are indicated by the LEDs (see “EasyLED Diagnostics”

in the Hardware Maintenance Manual).

2. Make sure that the server supports all the microprocessors and that the

microprocessors match in speed and cache size.

3. (Trained service technician only) Make sure that microprocessor 1 is seated

correctly.

4. Reseat the following components:

a. (Trained service technician only) Microprocessors

b. VRM, if microprocessor 2 is installed

5. (Trained service technician only) Replace the microprocessors.

Solving Ethernet controller problems

The method that you use to test the Ethernet controller depends on which operating
system you are using. See the operating-system documentation for information
about Ethernet controllers, and see the Ethernet controller device-driver readme file.

Try the following procedures:

144

ThinkServer RD220 Types 3729, 3779, 3797, and 3798: Hardware Maintenance Manual

This manual is related to the following products: