KTI Networks KS-2260 User Manual
Page 33
![background image](/manuals/158484/33/background.png)
-33-
The following 100FX modules are supported by F23 and F24 slots:
Part Number Connector
Cable
Distance
2260-FMT
Duplex ST
MMF*
2 km
2260-FMC
Duplex SC
MMF
2 km
2260-FJM
MT-RJ
MMF
2 km
2260-FVM
VF-45
MMF
2 km
2260-FSA2
Duplex SC
SMF*
20 km
Note:
* MMF - Multimode Fiber cable 50/125, 62.5/125
m
m
* SMF - Single Mode Fiber cable 8.7/125, 9/125, 10/125
m
m
Specifications
IEEE 802.3u 100BASE-FX compliant, Fixed 100Mbps, Fixed Full duplex
Optical Specifications
Part Number Wavelength Output Power
Input Optical Power
2260-FMT
1310nm
-19 ~ -14dBm
-31dBm min. -14dBm max.
2260-FMC
1310nm
-19 ~ -14dBm
-31dBm min. -14dBm max.
2260-FJM
1310nm
-20 ~ -14dBm
-31dBm min. -14dBm max.
2260-FVM
1310nm
-20.5 ~ -15dBm
-33dBm typ. sensitivity
2260-FSA2
1310nm
-18 ~ -7dBm
-32dBm max. sensitivity
Installation steps:
1. Turn the power to the switch off.
2. Set JP1.
3. Insert the 100FX modules and screw the modules securely.
4. Turn the power to the switch on.