Installation / panel-mounting

3.4 Securing the device with clamps

SIMATIC Panel PC 677B
Operating Instructions (Compact), 06/2008, A5E02217246-01

13

3.4

Securing the device with clamps

Requirement

Accessories

Display

12"

15"

17"

19"

6 x

6 x

8 x

8 x

Clamp

The clamps are provided with the control unit.

Tool

2.5 mm hexagonal spanner

Procedure

Figure 3-3

Clamp assembly


1. Disconnect the device from the power supply.
2. Working from the front, insert the device into the 19" rack on the swivel arm or in the

mounting cut-out.

3. Fasten the control unit from the rear using the clamps.
4. Tighten the setscrews to a torque of 0.4 - 0.5 Nm.

IP65 degree of protection

The plant builder is responsible for the correct installation of the device.

The degree of protection IP65 is only guaranteed for the front of the device if the ring seal is

properly applied with the correct size of cutout, the unit has been clamped in place, and the

instructions below are observed.

NOTICE

Control cabinet installation: Material strength at the mounting cut-out
Ensure that the material strength at the mounting cut-out is a minimum of 2 mm and a

maximum of 6 mm. Please follow the specifications for the dimensions in the "Preparing the

mounting cut-out" section.
The degrees of protection are only guaranteed when the following is observed:

The surface plane deviation of the mounting cut-out in relation to the external

dimensions of the control unit amounts to ≤ 0.5 mm when the control unit is mounted.