background image

Installation / panel-mounting

3.3 Preparing the mounting cut-out

SIMATIC Panel PC 677B
Operating Instructions (Compact), 06/2008, A5E02217246-01

11

3.3

Preparing the mounting cut-out

The following illustration shows the dimensions for the mounting cut-out.

PP

/

/

/

/

6

6

/

/

6

6

/

/

/

/

/

$

6

/

/

6

6

/

$

Figure 3-2

Drill holes for the screws and pressure points for the clamp screws

(1) Drill hole for screw attachment

(4)

Clamp

(2) Pressure points for clamp

(5)

R

Z

120 in the seal area

(3) Setscrews

(6)

Seal area

Note
Mounting dimensions can be read from the dimension overview or they can be transferred to

the cabinet from the mounting template supplied.