Siemens PAPBH User Manual
Model papbh - paradigm profibus host adapter, Description, Safety summary
1
!
2 RS232 PORTS (FOR HMI AND PC)
!
PROVIDES ACCESS TO PROFIBUS NETWORK THRU DB9
CONNECTOR
!
EASILY CONFIGURED USING EDICT97
!
BASE OR DIN RAIL (OPTIONAL) MOUNTING
!
STATUS LEDs
!
FIELDBUS TYPE : PROFIBUS-DP EN 50 170, IMPLEMENTED
USING SIEMENS SPC3 ASIC
!
AUTOMATIC BAUD RATE DETECTION IN THE RANGE
9.6 KBAUD – 12 MBAUD
!
STATION ADDRESS IS SET BY PROFIBUS NETWORK DRIVER
INSTALLED ON HMI PROGRAMMING PORT
!
FREEZE MODE AND SYNCH MODE ARE SUPPORTED
!
CONFIGURATION ALLOWS FOR SINGLE IDENTIFIER AND
SPECIAL IDENTIFIER DATA AREA DESCRIPTIONS, WITHOUT
DATA CONSISTENCY SUPPORT
DESCRIPTION
The PAPBH Paradigm PROFIBUS Host Adapter provides a communication
channel from a PROFIBUS-DP EN50170 Network to a Paradigm Operator
Interface (HMI). The PROFIBUS Network is connected to the PAPBH
(Paradigm PROFIBUS Host Adapter) through a 9-pin sub-miniature D-type
female connector. The PROFIBUS Network is isolated from the control
electronics using high-speed opto-couplers and isolated from the supply with a
DC/DC converter. Three LED’s provide status information.
The PAPBH can be base mounted (using the 4 holes provided in the base
plate) or DIN rail mounted (using the optional DIN rail mounting kit).
In normal operation the PAPBH is intended to be connected via it’s HMI port
to the programming port of the HMI. Database download can still be carried out
via a connection from the PC to the PC port of the PAPBH. All connections are
made using standard Red Lion Controls programming cables. Configuration is
by the PROFIBUS Network Driver installed on the HMI programming port.
On power up the PAPBH polls the HMI for its Station Address and
configuration. During start up the PROFIBUS master attempts to parameterize
and configure the PAPBH. Following start up, data is exchanged between the
PAPBH and the HMI.
PNO Conformance and GSD file
The PAPBH has passed the conformance test for PROFIBUS-DP Slave
Devices, Certificate No. Z00584. The PNO Identifier for this PROFIBUS
device is 0x00FC. The characteristics are described in GSD file
PCL00FC.GSD. A disk containing the GSD file and bitmap is included with
each PAPBH.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
ORDERING INFORMATION
SPECIFICATIONS
1. POWER REQUIREMENTS: 11 to 30 VDC @ 3.0 W
Power Up Current: 3 A @ 2 msec
Must use a Class 2 or SELV rated power supply.
2. SERIAL PORTS:
PC Port: RS232 on an RJ-11 jack.
HMI Port: RS232 on an RJ-11 jack.
ProfiBus Port: RS485 on a DB9 connector
3. PHYSICAL DIMENSIONS: L = 5.52" (140.2 mm), W = 4.52" (114.8 mm),
H = 1.76" (44.7 mm)
4. CONSTRUCTION: Steel base plate and cover. Installation Category I,
Pollution Degree 2
5. ENVIRONMENTAL CONDITIONS:
Operating Temperature: 0 to 40 °C
Storage Temperature: -20 to 80 °C
Operating and Storage Humidity: 80% max. relative humidity (non-
condensing) from 0 °C to 40 °C.
Altitude: Up to 2000 meters
MODEL PAPBH - PARADIGM PROFIBUS HOST ADAPTER
Bulletin No. PAPBH-X
Drawing No. LP0525
Effective 6/01
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion-controls.com
DIMENSIONS In inches (mm)
CAUTION: Read complete instructions prior to
installation and operation of the unit.
MODEL NO.
DESCRIPTION
PART NUMBER
PAPBH
PROFIBUS Host Adapter
PAPBH000
—
—
Programming Cable
PAPBH DIN Rail Mounting Kit
(Includes 4 clips and 8 screws)
P890301Z
PAPBHDIN