2 burner and nozzle characteristics table, 3 arrangement of the burners on the hob, Instructions for the installer – Smeg CP60X6 User Manual
Page 19
![background image](/manuals/152890/19/background.png)
Instructions for the Installer
64
15.2 Burner and nozzle characteristics table
Burner
Rated heating
capacity
(kW)
LPG – G30/G31 28/37 mbar
Nozzle
diameter
1/100 mm
By-pass
1/100
mm
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliaire
1.0
50
30
350
73
71
Semi rapid
1.75
65
33
450
127
125
Triple crown
3.2
91
65
1500
233
229
Burner
Rated heating
capacity
(kW)
NATURAL GAS – G20 20 mbar
Nozzle diameter
1/100 mm
Auxiliaire
1.0
72
350
Semi rapid
1.75
97
450
Triple crown
3.5
133
1500
15.3 Arrangement of the burners on the hob
BURNERS
1. Auxiliary
2. Semi rapid
4. Triple crown
ø min e max (in cm.)
12 - 14
16 - 24
18 - 26
This manual is related to the following products: