Synchronizing a transmitter with the receiver, Deactivating the lock mode temporarily – Sennheiser EM 2000 User Manual
Page 16
Using the receiver
14
̈
Set the headphone volume control
to the minimum position.
̈
Connect headphones with a ¼” (6.3 mm) stereo jack plug to the headphone output
.
̈
Gradually increase the volume and monitor the audio signal with the lowest possible
volume.
Synchronizing a transmitter with the receiver
You can synchronize a suitable transmitter of the 2000 series with the receiver. By default,
the following parameters are transferred to the transmitter during synchronization:
To transfer the parameters:
̈
Switch the transmitter and the receiver on.
̈
Press the
button
“
Sync
” appears on the display panel of the receiver.
̈
Place the infra-red interface of the transmitter (see the instruction manual of the trans-
mitter) in front of the infra-red interface of the receiver
The parameters are transferred to the transmitter. When the transfer is completed, “
”
appears on the display panel. The receiver then switches back to the current standard
display.
To cancel the transfer:
̈
Press the
STANDBY
button
“ ” appears on the display panel of the receiver. “ ” also appears if:
– no transmitter was found or the transmitter is not compatible,
– no transmitter was found and the synchronization process was canceled after
30 seconds,
– you canceled the transfer.
Deactivating the lock mode temporarily
You can activate or deactivate the automatic lock mode via the “
Auto Lock
” menu item (see
page 22). If the lock mode is activated, you have to temporarily deactivate it In order to be
able to operate the receiver:
B.Ch:
PEAK
EQ:
+ 1
P
-10
0
40
30
20
10
-20
-30
-40
AF
RF
True Diversity Receiver EM 2000
· »
Setting
Transferred parameters
“
Frequency Preset
” Currently set frequency
“
Name
”
Freely selectable name currently set on the receiver
“
Pilot Tone
”
Current pilot tone setting of the receiver (“
Inactive
”/“
Active
”)
Via the “
Sync Settings
” submenu, you can adjust additional parameters to be
transferred to the transmitters (see page 26).
¿ ´
¿ ´
̈
Press the jog dial or the
STANDBY
button.
“
Locked
” appears on the display panel.
̈
Turn the jog dial.
“
Unlock?
” appears on the display panel.
̈
Press the jog dial.
– When you are in the operating menu, the lock mode remains deactivated until
you exit the operating menu.
– When one of the standard displays is shown, the lock mode is automatically
activated after 10 seconds.