beautypg.com

2 burner and nozzle characteristics table, 3 arrangement of the burners on the hob, 1 auxiliary – Smeg SNZ61MFA1 User Manual

Page 21: 2 semi rapid, 3 wok, Final operations, Instructions for the installer

background image

Instructions for the installer

23

17.FINAL OPERATIONS

16.2 Burner and nozzle characteristics table

Burner

LPG (PROPANE)–2.75 KPA

NOMINAL GAS

CONSUMPTION

(MJ/H)

TURN-DOWN GAS

CONSUMPTION

(MJ/H)

INJECTOR

(MM)

Auxiliary

3.9

1.5

0.54

Semi rapid

6.3

1.5

0.68

WOK

12.8

5.4

1.00

Burner

NG –1.0 KPA

NOMINAL GAS

CONSUMPTION

(MJ/H)

TURN-DOWN GAS

CONSUMPTION

(MJ/H)

INJECTOR

(MM)

Auxiliary

3.9

1.5

0.90

Semi rapid

6.5

1.5

1.20

WOK

15.0

5.4

1.75

16.3 Arrangement of the burners on the hob

BURNERS

1 Auxiliary

2 Semi rapid

3 WOK

ø min e max (in cm.)

12 - 14

16 - 24

18 - 26

After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the grids.

Following adjustment to a gas other than the preset one, replace the gas adjustment label fixed to the
appliance with the one corresponding to the new gas. This label is in the packet together with the
nozzles.

17.1 Regulation of the hob burner minimum level for natural gas

Light the burner and turn it to the minimum position . Extract the gas tap knob
and turn the adjustment screw at the side of the tap rod until the correct minimum
flame is achieved.
Replace the knob and check burner flame stability: (rapidly turning the knob from
maximum to minimum position, the flame should not go out). Repeat the
operation on all the gas taps.

For models with valves, keep the knob at minimum level for about 1 minute to keep the flame lit and to
activate the safety device.