Instructions for the installer

19

15.INSTALLATION OF THE APPLIANCE

It is the law that all gas appliances are installed by authorised persons. Clearance around the cooker
must comply with the requirements of

AS5601

.

15.1 Electrical connection

Make sure that the power line voltage matches the specifications indicated on the rating plate located
inside the storage compartment.
This rating plate must never be removed.

On the power line, install a two-pole cut-off device with contact cut-off distance greater than or equal to 3
mm
, located in an easily accessible position near the unit.

The wire section on the cable must not be less than 2.5 mm

2

(3 x

2.5 cable), keeping in mind that the end to be connected to the
cooker must have the ground wire (yellow-green) longer by at least
20 mm. Use only the special cables available at our Service Centres.

The manufacturer declines all responsibility for damage to persons or things caused by non-
observance of the above prescriptions.

Overall dimensions: location of gas and electrical connection points (all measures in mm).