beautypg.com

Regarding the lamp (continued), Resetting the lamp timer – Sharp Notevision XR-32X User Manual

Page 58

background image

54

Remove the lamp unit.

• Loosen the securing screws from the

lamp unit. Hold the lamp unit and pull it
in the direction of the arrow. At this time,
keep the lamp unit horizontal and do not
tilt it.

Resetting the Lamp Timer

Reset the lamp timer after replacing the lamp.

Insert the new lamp unit.

• Press the lamp unit firmly into the lamp

unit compartment. Fasten the securing
screws.

Replace the lamp unit cover.

• Align the tab on the lamp unit cover

(1) and place it while pressing the tab
(2) to close it. Then tighten the user ser-
vice screw (3) to secure the lamp unit
cover.

4

5

6

Connect the power cord.

• Plug the power cord into the AC socket

of the projector.

Reset the lamp timer.

• While simultaneously holding down

MENU/HELP, ENTER and R on the pro-
jector, press STANDBY/ON on the pro-
jector.

• “LAMP 0000H” is displayed, indicating

that the lamp timer is reset.

• Make sure to reset the lamp timer only when

replacing the lamp. If you reset the lamp timer
and continue to use the same lamp, this may
cause the lamp to become damaged or ex-
plode.

1

2

Info

AC socket

• If the lamp unit and lamp unit cover are

not correctly installed, the power will not
turn on, even if the power cord is con-
nected to the projector.

Info

Regarding the Lamp (Continued)

Securing screws

ENTER button

MENU/HELP
button

R button

STANDBY/ON
button