beautypg.com

Maintenance indicators – Sharp Notevision XR-32X User Manual

Page 54

background image

50

Maintenance Indicators

About the lamp indicator

■ When the remaining lamp life becomes 5% or less, (yellow) and “Change The Lamp” will be

displayed on the screen. When the percentage becomes 0%, it will change to

(red), the lamp will

automatically turn off and then the projector will automatically enter standby mode. At this time, the
lamp indicator will illuminate in red.

If you try to turn on the projector a fourth time without replacing the lamp, the projector will

not turn on.

About the temperature warning indicator

If the temperature inside the projector increases, due to blockage of the air vents, or the setting location,

” will illuminate in the lower left corner of the picture. If the temperature keeps on rising, the lamp

will turn off and the temperature warning indicator will blink, the cooling fan will run, and then the projec-
tor will enter standby mode. After “

” appears, ensure you perform the measures described on

page

51

.

■ The warning lights (power indicator, lamp indicator and temperature warning indicator) on the

projector indicate problems inside the projector.

■ If a problem occurs, either the temperature warning indicator or the lamp indicator will illuminate

red, and the projector will enter standby mode. After the projector has entered standby mode,
follow the procedures given below.

Red on

Green on

Red blinks

Green blinks

Green on

Green blinks

Red on

Off

Red on

Power indicator

Lamp indicator

Temperature warning
indicator

Indicators on the Projector

Normal (Standby)

Normal (Power on)

Abnormal (See page

51

.)

Normal (Cooling)

Normal

The lamp is warming up.

The lamp is shut down abnormally or requires to be
changed. (See page

51

.)

Normal

The internal temperature is abnormally high. (See page

51

.)

Top View

Lamp indicator

Temperature warning
indicator

Power indicator