Errors, Temperature exceeded, Fan failure – Smart Technologies 600i3 User Manual
Page 59
![background image](/manuals/151347/59/background.png)
47 |
CHAPTER 6 – TROUBLESHOOTING YOUR SMART BOARD 600I 3 OR SBD600I3
INTERACTIVE WHITEBOARD SYSTEM
Errors
Temperature Exceeded
If the Temperature Exceeded indicator message appears and your projector turns off
during use, one of the following issues is occurring:
•
Your projector overheated internally. The projector can overheat because of
blocked air vents or an internal temperature over 131°F (55°C).
•
The temperature outside your projector is too high.
To resolve
the temperature
exceeded error
1. Wait 15 minutes for the projector to cool down before attempting to restart.
2. Make sure that nothing is blocking the air intake and exhaust.
3. Disconnect the power cord from the power outlet.
4. Reconnect the power cord.
5. If the previous steps don’t resolve the issue and your projector still doesn’t turn on,
unplug the power cord, and then contact your
Fan Failure
If the Fan Failure indicator message appears and your projector turns off during use,
one of the following issues is occurring:
•
One of the fans has failed.
•
Your projector is overheating internally.
To resolve your
fan failure error
Disconnect the power cord, and then contact your
Error (Temperature
Exceeded)
Off
Flashing Red
Error (Fan Failure)
Off
Solid Red
Error (Color Wheel
Failure)
Off
Solid Red
Error (Lamp Failure)
Solid Amber
Flashing Red
Message
Power LED
(Green/Amber)
Temperature LED
(Red)