Siemens SCALANCE X-200 User Manual
Page 48
Product Characteristics
4.4 SCALANCE X206-1
0 – 85 m
0 -3,000 m
IE FC marine/trailing cable with IE FC RJ-45 plug
180
or
IE FC marine/trailing cable (0 - 75 m) + 10 m TP
cord
Glass FOC
62.5/125 µm or 50/125 µm glass fiber;
≤ 1 dB/km at 1300 nm;
600 MHz x km;
6 dB max. permitted FO cable attenuation with 3
dB link power margin
Aging time
Aging time
5 minutes
Permitted Environmental Conditions / EMC
Operating temperature
0° C through +60° C
Storage/transport temperature
-40° C through +80° C
Relative humidity in operation
‹ 95% (no condensation)
Operating altitude
2000 m at max 56 °C ambient temperature
3000 m at max. 50 °C ambient temperature
RF interference level
EN 50081-2 Class A
Noise immunity
EN 50082-2
Degree of protection
Tested to IP30
Approvals
UL 60950
c-UL-us
CSA C22.2 No. 60950
c-Ul-us for hazardous locations
UL 1604, UL 2279Pt.15
FM
FM 3611
C-TICK
AS/NZS 2064 (Class A).
CE
EN 50081-2, EN 50082-2
ATEX Zone 2
EN50021
MTBF
MTBF
42.56 years
Construction
Dimensions (W x H x D) in mm
60 x 125 x 124
Weight in g
780
Installation options
Standard rail
S7-300 standard rail
Wall Mounting
Order Numbers
SCALANCE X206-1
6GK5206-1BB00-2AA3
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
4-34
Commissioning Manual, 1,