beautypg.com

Scalance x108 technical specifications, 8 scalance x108 technical specifications – Siemens SCALANCE X-200 User Manual

Page 20

background image

Product Characteristics

4.1 SCALANCE X108

Power indicator (green LED)

The status of the power supply is indicated by two green LEDs:

Status

Meaning

lit green

Power supply L1 or L2 is connected.

not lit

Power supply L+ is not connected or <14 V

Port status indicator (green/yellow LEDs)

The status of the ports is indicated by eight LEDs:

Status

Meaning

Port 1 through 8 LED lit green

TP link exists, no data reception

Port 1 through 8 LED lit yellow

TP link exists, data received at TP port

Ports 1 through 8 LED flash yellow Setting or display of the fault mask

4.1.8

SCALANCE X108 Technical Specifications

Technical Specifications of the SCALANCE X108

Ports
Attachment of DTEs or network components over

twisted pair

8 x RJ-45 sockets with MDI-X pinning 10/100

Mbps (half/ full duplex)

Connector for power supply

1 x 4-pin plug-in terminal block

Connector for signaling contact

1 x 2-pin plug-in terminal block

Electrical Data
Power supply

2 x 24 V DC

(18 - 32 V DC)

safety extra-low voltage (SELV)

Power loss at DC 24 V

3.36 W

Current consumption at rated voltage

140 mA

Overvoltage protection at input

PTC resetable fuse (0.6 A / 60 V)

Permitted Cable Lengths
Network span parameter/TP cable length
0 – 100 m


0 – 85 m


IE FC standard cable with IE FC RJ-45 plug 180

or

over IE FC outlet RJ-45 with 0 - 90 m IE FC

standard cable + 10 m TP cord
IE FC marine/trailing cable with IE FC RJ-45 plug

180

or

0 - 75 m IE FC marine/trailing cable + 10 m TP

Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line

4-6

Commissioning Manual, 1,

This manual is related to the following products: