Siemens SCALANCE X-200 User Manual
Page 38
Product Characteristics
4.3 SCALANCE X208PRO
connector
Aging time
Aging time
5 minutes
Permitted Environmental Conditions / EMC
Operating temperature
-20° C through +70° C
Storage/transport temperature
-40° C through +80° C
Relative humidity in operation
‹ 95% (no condensation)
Operating altitude
2000 m at max 56 °C ambient temperature
3000 m at max. 50 °C ambient temperature
RF interference level
EN 50081-2 Class A
Noise immunity
EN 50082-2
Degree of protection
IP65
Approvals
UL 60950
c-UL-us
CSA C22.2 No. 60950
c-Ul-us for hazardous locations
UL 1604, UL 2279Pt.15
FM
FM 3611
C-TICK
AS/NZS 2064 (Class A).
CE
EN 50081-2, EN 50082-2
ATEX Zone 2
EN50021
MTBF
MTBF
25.56 years
Construction
Dimensions (W x H x D) in mm
90 x 125 x 124
Weight in g
950
Installation options
Wall mounting
DIN rail
ndard rail
Order Numbers
SCALANCE X208PRO
6GK5208-0CA00-2AA6
"Industrial Ethernet TP and Fiber Optic Networks"
manual
6GK1970-1BA10-0AA0
IE FC Stripping Tool
6GK1901-1GA00
IE FC blade cassettes
6GK1901-1GB00
IE FC TP standard cable
6XV1840 2AH10
IE FC TP trailing cable
6XV1840-3AH10
IE FC TP marine cable
6XV1840-4AH10
C-PLUG
6GK1 900-0AB00
Power M12 cable connector PRO
6GK1 907-0DC10-6AA3
Signaling contact M12 cable connector PRO
6GK1 908-0DC10-6AA3
Power supply PS791-1PRO
6GK5 791-1PS00-0AA6
Power cord M12
6GK1 907-0AF00-0AA0
S7-300 sta
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
4-24
Commissioning Manual, 1,