beautypg.com

Scalance x208 tp ports – Siemens SCALANCE X-200 User Manual

Page 24

background image

Product Characteristics

4.2 SCALANCE X208

4.2.4

SCALANCE X208 TP Ports

Connector Pinout

On the SCALANCE X208, the TP ports are implemented as RJ-45 sockets with MDI-X

assignment (Medium Dependent Interface–Autocrossover) of a network component.

Notice
TP cords or TP-XP cords with a maximum length of 10 m can be connected to the RJ-45 TP

port.
With the IE FC cables and IE FC RJ-45 plug 180, an overall cable length of a maximum of

100 m is permitted between two devices.

Autonegotiation

Autonegotiation means the automatic detection of the functionality of the port at the opposite

end. Using autonegotiation, repeaters or DTEs can detect the functionality available at the

port of a partner device allowing automatic configuration of different types of device. With

autonegotiation, two components connected to a link segment can exchange parameters

and set themselves to match the supported communication functionality.

Note
Devices not supporting autonegotiation must be set to 100 Mbps/ half duplex or 10 Mbps

half duplex.

Note
The SCALANCE X208 is a plug-and-play device that does not require settings to be made

for commissioning.

MDI /MDIX Autocrossover Function

The advantage of the MDI /MDIX autocrossover function is that straight-through cables can

be used throughout and crossover Ethernet cables are unnecessary. This prevents

malfunctions resulting from mismatching send and receive wires. This makes installation

much easier for the user.
The devices of the SCALANCE X-100 and X-200 product lines all support the MDI / MDIX

autocrossover function.

Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line

4-10

Commissioning Manual, 1,

This manual is related to the following products: