Product Characteristics
4.3 SCALANCE X208PRO
Port status indicator (green/yellow LEDs)
The status of the ports is indicated by eight two-color LEDs:
Status
Meaning
Port 1 through 8 LED lit green
TP link exists, no data reception
Port 1 through 8 LED lit yellow
TP link exists, data received at TP port
Device startup, the LED is lit for approx. 6s.
Ports 1 through 8 LED flash yellow Setting or display of the fault mask
Port 1 through 8 LED flashes green The "Show Location" function was activated over Ethernet (e.g.
PST tool).
LED Display during Startup
Following startup, the following LEDs light up in the following order:
• Power LEDs (green) light up immediately after turning on the power.
• Port LEDs (yellow) light up for approx. 6 s, the red LED is off.
• Port LEDs go off, the red LED is lit for approx. 20 s.
After the port LEDs go off, the correct link status is displayed after approx. 2 s.
The device is now ready for operation.
4.3.8
SCALANCE X208PRO Technical Specifications
Technical Specifications of the SCALANCE X208PRO
Ports
Attachment of DTEs or network components over
twisted pair
8 x RJ-45 sockets with MDI-X pinning 10/100
Mbps (half/ full duplex)
Connector for power supply
2 x 4-pin M12 port (a-coded)
Connector for signaling contact
5-pin M12 port (b-coded)
Electrical Data
Power supply
2 x 24 V DC
(18 through 32 V DC)
Power loss at DC 24 V
4.4 W
Current consumption at rated voltage
185 mA
Overvoltage protection at input
PTC resetable fuse (0.6 A / 60 V)
Permitted Cable Lengths
Network span parameter/TP cable length
0 -100 m
0 - 85 m
IE FC standard cable with IP67 push pull
connector
IE FC marine/trailing cable with IP 67 push pull
safety extra-low voltage (SELV)
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
Commissioning Manual, 1,