Instructions for the installer, Installation of the appliance – Smeg A1.1K User Manual
Page 6

Instructions for the installer
40
2. INSTALLATION OF THE APPLIANCE
It is the law that all gas appliances are installed by
competent persons
.
Corgi gas installers are approved to work to safe and satisfactory 
standards. All gas installation, servicing and repair work must be in 
accordance with the gas safety regulations 1984 (installation and use) as 
amended 1990. 
It can be placed against walls higher than the hob, at a distance of at 
least 50 mm from the side of the appliance, as shown in the drawings A 
and B relating to the installation classes. Wall units or extractor hoods 
located above the hob must be at least 750 mm away from it.
A
B
SLOT IN
FREE STANDING
2.1 Electrical connection
Make sure that the power line voltage matches the specifications 
indicated on the rating plate located inside the storage compartment. 
This rating plate must never be removed. 
The plug at the end of the power cable and the wall socket must be the 
same type (conforming to regulations in force). Check that the power line 
is adequately grounded. Do not use reducers, adapters or shunts. 
On the power line, install an omnipolar cut-off device with contact cut-off 
distance greater than or equal to 3 mm, located in an easily accessible 
position near the unit. 