beautypg.com

SMC Networks ROBO Cylinder RGD4D User Manual

Page 42

background image

32

13.3 Notes


Take note of the following points if you are using a high acceleration/deceleration type:
(1) Keep the duty within 50%. If the duty exceeds 50%, an overload error may occur.
(2) The maximum loading capacity follows the applicable value specified in the table under

“Specifications of High acceleration/Deceleration Actuators” regardless of the acceleration setting.

(3) Refer to p. 29 for the maximum speed.

13.4 Applicable Controller Models (SCON, SSEL, X-SEL)


The following code is appended after the encoder type:
HA: High acceleration/deceleration specification
(Blank): Conventional

specification

(Examples) [1] High acceleration/deceleration specification

SCON-C-20IHA-NP-2-0

[2] Conventional specification

SCON-C-20I-NP-2-0



The applicable controllers vary depending on the actuator specification. Check the model of the actuator
you will be using.